Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Type of study
Year range
1.
International Eye Science ; (12): 1807-1811, 2017.
Article in Chinese | WPRIM | ID: wpr-641105

ABSTRACT

AIM: To evaluate the efficacy and safety of a new implant, Suprajet ( VSY Biotechnology, Istanbul, Turkey ) , which is developed for supraciliary and suprachoroidal drainage of aqueous humour. ·METHODS: Five rabbits were included in the study. One Suprajet shunt was implanted in one eye of each rabbit. Implantation was performed by a superior clear corneal incision through the anterior chamber into the suprachoroidal space. Proximal end of the implant was placed in the iris root resting against the scleral spur, distal end was placed in the suprachoroidal space. Rabbits were followed for 4wk. Preoperative and postoperative intraocular pressure ( IOP ) levels were measured with Tonopen AVIA. At last follow-up visit animals were sacrificed and eyes were enucleated. Macroscopic and histopathologic evaluation of the eyes were made. ·RESULTS:Mean preoperative IOP was 18. 6±6. 1 mmHg. Mean postoperative IOP was 8. 4 ± 1. 1 mmHg, at one week. At the 2nd week of the follow-up period one rabbit died. Thereafter, only 4 rabbits were followed. Mean postoperative IOP was 11. 0 ± 2. 8 mmHg at the 2nd week, 9. 50±3. 1 mmHg at the 3rd week and 11. 3 ±3. 3 mmHg at 4th week after the operation. When mean preoperative IOP was compared with the postoperative IOP values, only the IOP at the first week was found as significantly lower ( P=0. 042). There was no statistically significant difference between mean preoperative IOP level and mean IOP level at 2, 3 and 4wk postoperatively (P=0. 66, P=0. 66 and P=0. 102, respectively). As an intraoperative complication, minimal hyphema was noted in three eyes during the surgery. However, the next day hyphema cleared completely. Macroscopic evaluation of the enucleated material showed that in one eye the distal end of the implant was in the vitreous instead of suprachoroidal space, in the other 3 eyes the distal end of the implant was noted in the suprachoroidal space. In all eyes, proximal end of the implant was localized in the anterior chamber angle. Histopathologic evaluation of the enucleated eyes showed deposition of irregular collagen bundles and fibroplasia including numerous fibroblastic and histiocytic cells around the implant. ·CONCLUSION: This preliminary animal study showed that implantation of Suprajet in glaucoma is a promising procedure. Further studies are needed to evaluate its efficacy and safety profile.

2.
Arq. bras. oftalmol ; 79(1): 53-55, Jan.-Feb. 2016. graf
Article in English | LILACS | ID: lil-771905

ABSTRACT

ABSTRACT Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a novel surgical technique for the management of an aphakic eye with traumatic aniridia for a patient who underwent transscleral fixation of a custom-tailored artificial iris prosthesis combined with a rigid intraocular lens (IOL). Tight suturing of the IOL haptic eyelets on the silicone iris prosthesis and fixation of such a complex to the scleral wall may provide excellent cosmetic and functional outcomes in aphakic eyes with aniridia.


RESUMO Aniridia pós-traumática combinada com afacia pode ser observada após lesões do globo ocular. Além do ponto de vista estético, a perda parcial ou total do tecido da íris também pode estar relacionada com vários graus de ofuscamento e fotofobia. Estes pacientes sofrem de deficiência visual grave secundária a afacia. Relata-se uma técnica cirúrgica inovadora para tratamento de um olho com afacia associada à aniridia traumática que foi submetido à fixação transescleral de uma prótese de íris artificial feita sob medida combinada com uma lente intraocular rígida (IOL). A sutura das alças da IOL sobre a prótese iriana de silicone, e a fixação desse complexo na parede escleral podem proporcionar excelente resultado estético e funcional em olhos afácicos com aniridia.


Subject(s)
Female , Humans , Middle Aged , Aniridia/surgery , Aphakia/surgery , Iris/surgery , Lenses, Intraocular , Prostheses and Implants , Sclera/surgery , Aniridia/etiology , Aphakia/etiology , Eye Injuries/surgery , Lens Implantation, Intraocular/methods , Prosthesis Design , Treatment Outcome , Visual Acuity
3.
Indian J Ophthalmol ; 2014 Aug ; 62 (8): 876-878
Article in English | IMSEAR | ID: sea-155730

ABSTRACT

We describe a technique to manage late spontaneous intraocular lens (IOL) and capsular tension ring (CTR) dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fi xed to the pars plana at both 3 and 9 o’clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and eff ective surgical option for such cases.

SELECTION OF CITATIONS
SEARCH DETAIL